Find great deals for Hörmann Universaladapterplatine UAP 1. Shop with confidence on eBay!. For Hörmann door, Type: SupraMatic, Rotamatic / P / PL from year 09/ and LineaMatic built from 10/ – About for direction selection (up / stop / close). For inputs to Hormann: does it mean that I have to run 6 wires for this section from Loxone to Hormann? Or is it possible to reuse the wire for

Author: JoJosida Dorisar
Country: Guatemala
Language: English (Spanish)
Genre: Medical
Published (Last): 8 May 2005
Pages: 377
PDF File Size: 15.99 Mb
ePub File Size: 16.20 Mb
ISBN: 321-5-51170-689-8
Downloads: 84308
Price: Free* [*Free Regsitration Required]
Uploader: Faut

The only horman I get from what is stated is that if you press to open – you press the button again to stop it not a true move up move down motion.

Pedestrian door Bit 6: Hardware Top side of the circuit board: I hoped to find the signals there as well but it turned out ua;1 is not the case.

They make me able to export the analyzed data as CSV. So I decided to reverse engeneer and document the bus!

Ken 4, 1 4 Whith that one I can tell when the UAP1 is sending and when it is receiving! Hi Ken, as you say in the beginning of the reply the UAP enables me to “open the garage door” and “close the garage door” which is what I want to achieve same as what the person who wrote the guide I linked to achievedsorry if I didn’t explain properly.

Dominik Hadl 51 4. Exactly what I want to have: But at least I can connect to GND there.

Hörmann Universaladapterplatine UAP 1 | eBay

Looking at the other link for the Hormann website using translation – it looks like they indicate it hofmann do a partial open: That means you have just very basic control over the motor because you can’t give up and down command but just a go command as you can with the radio controls. This is how far i got until now. Unfortunately no other communication is happening when I trigger a “close door” for example. That tells me that it appears your UAP will not allow for the individual movements that you are looking to achieve.

  ERIK FROM UMECE LJUBAVI PDF

Sign up using Facebook. RS is Half-Duplex, that means that only one participant on the bus can talk at a given time. Any help would be greatly appreciated. But how can I tell who is sending which bytes!? I might misinterprete some of them at this point: Post as a guest Name. Sign up or log in Sign up using Google. That way I’m able to trace the bus in realtime without the need to leave the house It’s pretty cold uapp1 at this time of the year.

When the board is powered while the usp1 analyzer is collecting data, we see these bytes comming in:. Reverse engeneering the protocoll I expected a rather simple protocoll where no comunication happens until the UAP1 gets triggered by a switch, but I was more than wrong.

To dig deaper into the protocoll I need more data. Thanks for looking into this! I am an electronics amateur and can’t figure out based on the schematic below if that is correct?

No common CRC8 generator gave me the same result as the messages have. After being able to seperate the byte uxp1 into messages, I still wasn’t able to calculate the checksum. I’ve set two analyzers for async serial data on both, the RX and the TX line. Why it doesnt scan the adresses down to ?

By using our site, you acknowledge that you have read and understand our Cookie PolicyPrivacy Policyand our Terms of Service. According to the Guide you posted The UAP enables you to control the light of the supramatic open the garage door close the garage door stop the garage door check whether the door is totally closed or totally open, light status?

  BEHRINGER ULTRAMATCH SRC 2000 PDF

Reverse engeneering the Hörmann UAP1 protocoll

I decided to look at the boards communications without the motor connected. To supply the board with 24VDC, which normally comes in via the RJ12 connector, I simply used the terminals taht normally connect the switches.

At startup the Master scans the bus for devices. Broadcast status From the beginning the master sends a broadcast status message. Dynamically assigned by the master As you can see the only status bit set, is from the second byte and means reversing according to the patent which makes no sense to me.

Email Required, but never shown. Home Questions Tags Users Unanswered. It seems that this must happen when the UAP1 is connected to the motor. The changed partial opening position is saved. Radio control getting teached Bit 2: Bottom side of the circuit board: For that to work I needed to buy a UAP universal adapter, meant for hprmann like these and connect it to my Loxone miniserver.

The remotes require a 2 second press to avoid accidental presses, have you tried making your pulse longer? Here’s what I got using the USB converter with the door closed idling:. I see one for your supramatic seems a bit over complicated for a Garage Door – however reading the instructions for the ventilation position You might find what you need here.